Accuster Technologies Pvt. Ltd. Brochure

Item

Title
Accuster Technologies Pvt. Ltd. Brochure
extracted text
SDA-RF-AT-3.10

President of India Shri Pranab Mukherjee

Technology
S Jaipal Reddy

President of India

Accuster Meet Dr. Harsh Vardhan - Minister of Health

Minister of Science & Technology Dr. Jitender Singh appreciating
our Innovation LaBike in the event of DSIR

and Family Welfare

Accuster Technologies Pvt. Ltd.
Plot No. 758, First Floor, Sector 47, Gurgaon - 122018, Haryana, India
Office: 0124-4362 202 | Sales : +91 8527895900/01 | Customer Care: 0124-4500 700/011 Web: WWW.ACCUSTER.COM

Certifications & Awards

|Care|
ACCUSTER TECHNOLOGIES
PVT. LTD.
OmCE : SECTOR - 47, PLOT NO. 758. GURGOAN
(HARYANA) (INDLA)
PLANT: SECTOR - 8, PLOT NO. 41. EMT MANESAR
(HARYANA) (INDLA)

MEDICAL DEUCES - QUALITY MANAGEMENT SYSTEM

ISO 13485:2003
MANUFACTURING AND SUPPLY OF MEDICAL DIAGNOSTIC
PRODUCT ACCURATE ALL (SMALL BLOOD ANALSTERX
C ENTR1FUGE. INCUBATOR. MOBILE LAB. REAGENTS JOTS.

GtfE QKTlFKAnON PkYATI IM TED
IMA
VkXww* Vi*KiM

U.S FDA Certification

ISO 13485:2003

Patented Technology

PT RiyTTTTP POST

CE Certification

DSIR Lab Recognised

Fin
IBM
Awarded to

Accuster Technologies
for participating in too

IBM Global Entrepreneur Mentor Day
Bangalore, 24th July 2013

AllMS Awards

IBM Awards

4
Pathology Mobile Lab

®
Patented Technology

m

Vtio

"Innovation That Matters

dsirtdb

Mobile Lab is Compact Portable Clinical Laboratory In a suitcase having Power Back- Up which contains
Biochemistry Analyzer ACCU-ALL /Accu kine , Centrifuge, Incubator, Data Recorder/Mini Laptop with Patient

Data Management Software, Micropipettes and other accessories. It performs - UPID, RENAL, LFT, KFT, Electrolytes,

Glucose, Haematology - 5 Tests.

It has a proper place for each and every component of Lab and It is so rugged that can be easily carried to the
far flung and remotest locations.

Lab in a Box/Lab on Wheels
Open System

Innovative Thinking Leads to

Portable

Revolutionary Technology

Rugged Analyzer
Temperature Stability

*
*

Low Power Consumption

Less Chemical Consumption

Humidity & Climate independent

<— with Solar Panel

Maintenance Free - Replaced Delicate

Mechanism with Rugged Technology
Reading time of Analyzer is only 2 seconds

Highly Accurate and Linearity up to 4 times
No warm up time & cooling time Is required
Blood collection cost is 1/20th of other Labs

Power Backup - 4 Hours Extendable to 24 hrs

Quick ROI - in Just 30 Days
Mobile Lab Versions Available

PCML - All

PCML - Kine

Satellite Control: Switching Off The Labs From Remote Distance

Test Reports Are Accessible Through Website
Instant Reporting
Instant Data transfer from Lab to Laptop/Data Recorder via Bluetooth
Real Time Data Transfer to Headquarters During field testing

TRAINING ON
i) Maintaining High Standards of Tests Results | ii) Executing Field Medical Camps
Sugar: Glucose
KFT: Creatinine | Urea | Uric Acid | BUN | EGFR
LFT : Albumin | Alkaline Phosphatase | Direct Bilirubin | Indirect Bilirubin | Total
First Time in Healthcare History : Doorstep Testing

Bilirubin | AST(SGOT) | ALT(SGPT) | Total Protein | Globulin | AG Ratio

Became Easy & Cost Effective with Reliable Test
Results (Less Than 3% Variation)

Validated at: AllMS. R&R Army Hospital. ITBP,

Various State’s General Hospitals etc...

Rocommondcd by ICMR. Rotary Club otc.

Hematology : Haemoglobin | RBC | PCV | MCV | MCH | MCHC

Upid Profile: Cholesterol | HDL | Triglyceride | LDL | LDL Calculative | VLDL | HDL/LDL

Ratio | Cholesterol/HDL ratio | CK_MB
Electrolytes: Sodium | Potassium | Chloride | Phosphorus | Calcium | Magnesium

ON DGS&D Rate Contract NO.PCML/AM-4/RC-CD020000/0715/74/NB107/1061 Valid Till 31-03-2015

W World's First LaBike
“Latest Innovation of Accustcr”

Patented Technology

Export in Vilio Diognortics

DSIR TDB

Complete laboratory will be retrofitted on client’s motor- bike with complete framework to keep
listed equipments with bio waste management facility with power back up and GPRS Tracker

MOBILE LAB

MICROSCOPE
ECG KIT
SEROLOGY KIT

UROLOGY KIT

((L 3

BP MACHINE

HEIGHT & WEIGHT
COLD CHAIN (~2°C)

DATA RECORDER
GPS & WEB CAM

SERVER SUPPORT
SATELLITE CONTROL

76
TESTS

BIOWASTE MANAGEMENT

POWER BACKUP
FOLDABLE TENT

BIOCHEMISTRY | HEMATOLOGY | SEROLOGY |

FOLDABLE CHAIR

UROLOGY | ECG | BP & BMI | ONLINE REPORTING

FOLDABLE STOOL

Tests Performed on LaBike
BIOCHEMISTRY |
Glucose
Direct Bilurubln

Electrolytes

Fasting

Calcium

HEMATOLOGY

SEROLOGY

URINE

Hemoglobin

Widal

Leukocyte

WBC (TLC)

Typhl Dot Igm

Nitrite

Lymphocyte

Maleria Antigen

Billnogen

Granulocyte

Dengue NS1 Antigen

Protein

RBC

HBSAG

PH

HCT

HCV

Blood

MCV

VDRL

MCH

RA Factor

Urea

MCHC

CRP

Uric Acid

PCV

Pregnancy ( UPT)

LFT

EGFR

Platelet

Semen Analysis

AG Ratio

Creatinine

PCT

Semen Fructose

Random

Albumin

SGOT

Chloride

Lipid Profile

SGPT

Sodium

HDL

ALP

Potassium

LDL

Total Protein

Magnesium

VLDL

Indirect Bilirubin

Phosphorus

BUN

ECG

PP

Triglyceride

HDL/LDL Ratio
Chciederoi HDL Reto
Cholesterol

Globulin

Total Bilurubin

Validated at AllMS. R&R Army Hospital. fTBP.
Various State's General Hospitals etc..

Recommended by ICMR. Rotary Club etc...

TEMPERATURE

Ketone

Bilirubin

Glucose

Apperance
Colour

PLCR

Reaction

PLCC

Quantity

Bacteria^^-

Cost Effectiveness of LaBike

First Timo in Healthcare History : Doorstep Testing
Became Easy & Cost Effective with Reliable Test

Results (Less Than 3% Vanation)

BMI

Specific Gravity

Cost Component
Vehicle
Operating Cost (per 100km)
Component Cost
Driver Salary
Total Cost Per Vehicle

75k
lOORs

12 Lacks
Ik
10-12 Lacks (approx)

4.5 Lacks

Wmonth
——^^24.13Lacks

0
4.70 Lock*

ON DGS&D Rate Contract NO.PCMUAM^Rc^DOZOOOO/Oris^NBIOr/IOBI Valid Till 31^ 5

4
Compact Static Lab
Patented Technology

DSIR TDB

“Innovation That Matters”

IT is Compact Portable Clinical Laboratory in a suitcase containing Biochemistry Analyzer ACCUKINE/ACCU ALL, Centrifuge, Incubator, Data Recorder/Mini Laptop with Patient Data Management
Software, Micropipettes and other accessories. It performs - LIPID, RENAL, LFT, KFT, Electrolytes,

Glucose, Haematology - 5 tests.

* Open System

* Highly User
*

* Less

* 24

* Highly
*

Running Cost is Rs 91 for All Tests

Static Lab Versions Available
PCSL-ALL | PCSL-KINE

• Satellite Control: Switching Off The Labs From Remote Distance

• Test Reports Are Accessible Through Website
• Instant Test Reporting
• Instant Data transfer from Lab to Laptop/Data Recorder via Bluetooth
• Real Time Data Transfer to Headquarters During field testing

TRAINING ON
i) Maintaining High Standards of Tests Results | ii) Executing Field Medical Camps
Sugar: Glucose

KFT: Creatinine | Urea | Uric Acid | BUN | EGFR
LFT : Albumin | Alkaline Phosphatase | Direct Bilirubin | Indirect Bilirubin | Total
First Timo in Healthcare History : Doorstep Testing
Became Easy & Cost Effective with Reliable Test

Bilirubin | AST(SGOT) | ALT(SGPT) | Total Protein | Globulin | AG Ratio

Results (Loss Than 3% Variation)

Hematology: Haemoglobin | RBC | PCV | MCV | MCH | MCHC
Validated at: AllMS. R&R Army Hospital. ITBP,

Lipid Profile: Cholesterol | HDL | Triglyceride | LDL | LDL Calculative | VLDL | HDL/LDL

Various State’s General Hospitals etc...

Ratio | Cholesterol/HDL ratio | CK_MB
Recommended by : ICMR, Rotary Club etc...

Electrolytes: Sodium | Potassium | Chloride | Phosphorus | Calcium | Magnesium

ON DGS&D Rate Contract NO.PCML/AM-4/RC-CD020000/0715/74/NB1 07/1061 Valid Till 31-03-2015

export tn VHro Diagnoses

Patented Technology

Test List
Sugar:

” ECO-SMART ANALYZER

Glucose

KFT :
Creatinine
Urea

Uric Acid
BUN

Based on LED, Patented Technology

EGFR

Open System

LFT :
Albumin
Alkaline Phosphatase
Direct Bilirubin
Indirect Bilirubin
Total Bilirubin
AST(SGOT)
ALT(SGPT)

Total Protein
Globulin
AG Ratio

Hematology :
Haemoglobin
RBC
PCV

MCV

MCH
MCHC

Lipid Profile :
Cholesterol
HDL
Triglyceride
LDL
LDL Calculative

VLDL

HDL/LDL Ratio
Cholesterol/HDL ratio

*

I RHM S3

HHH
HHH

Lightest in Weight

oaa

Highly User Friendly

*
*
*
*
*
*
*

Memory of 3,000 Reports.
Less Reagent Consumption
Lesser Cost of Kinetic Tests
Low Power Consumption (4watt).

AccuKine Versions

AccuALL Versions

ACCU-KINE | ACCU-KINE +
(UV & Visible Light)

ACCU-ALL | ACCU-ALL +
(Visible Light)

Highly Accurate and Linearity up to 4 times

Clinical Biochemistry Test (32 parameters) & 5 Haematology Parameters
20 times more life compared to present Analyzer

Portable, very Rugged and Reliable Analyzer

Unique way of Calibration which is Quite Cost Effective.
Maintenance free - Replaced Delicate Mechanism with
Rugged Technology (No filter No Lamp)
Stable Performance
i) It is more precise and Accurate.

Online Reporting Format

il) Internal Thermal Sensitive Printer

CK MB ( with Accu-Kine)

Electrolytes :
Sodium
Potassium
Chloride
Phosphorus

Calcium
Magnesium

Satellite Control: Switching Off The Labs From Remote Distance
first Time in Healthcare History : Doorstop Testing
pecamo Easy & Cost Effective with Reliable Tost
Results (Loss Than 3% Variation)

Test Reports Are Accessible Through Website
Instant Reporting

validated at; AllMS. R&R Army Hospital. ITBP.

various State's General Hospitals etc...

f?ccomtnon(jod by

|CMR Rotary Club otc...

Instant Data transfer from Lab to Laptop/Data Recorder via Bluetooth
Real Time Data Transfer to Headquarters During field testing

°GS&D Rate Contract NO.PCMUAM-4/RC-CD020000/0715/74/NB1 07/1061 Valid Till 31-03-2015

Market Rates Vs Running Costs of Accuster Lab
Our Price List

MRP IN MARKET (INR)

TEST

Sr. No.

SUGAR

1

"

1

- ■— ’■

Glucose

I. .

.



"

l

80

050

90

0.70

HEMATOLOGY
2

Haemoglobin
LFT
..

. ..........................................................

......

............

.

....
2M

3

Total Bilirubin

110

4

Direct Bilirubin

110

2.40

5

Albumin

100

1.60

6

SGOT

140

4.85

7

SGPT

140

5.0

8

ALP

120

5.0

9

Total Protein

140

1.50

Uric Acid

120

3.58

Urea

100

2.54

12

Creatinine (kin)

110

5.30

13

Creatinine (End)

110

3.30

2.32

.. .

!
|

KFT
10
11

1

ELECTROLYTES
14

Calcium

110

15

Chloride

120

16

Sodium

120

8.50

17

Potassium

120

9.50

Magnesium

180

4.70

Phosphorus

120

4.80

19

....

2.25
..........

LIPID PROFILE

I

20

HDL

180

21

LDL

180

2.18

22

Cholesterol

210

5.40

23

Triglycerides

180

10.30

Total =2990

Total =91.20



Comparison between Accuster Mobile Lab and Others
Sr. No

Other Conventional Labs

Mobile Lab

Non portable and highly sensitive device

1

Portable and Rugged Device

It is a whole clinical biochemistry laboratory that is handy and

Requires

2

easily transportable. Lab in a box, it contain all instruments

condition Biochemistry analyzer is a machine on which we can

where Biochemical Analyzer is only one component.

read the concentration of biochemical parameters of blood.

It contains Biochemistry Analyzer, Centrifuge, Incubator, Data

Here all other required components has to be bought separately. Lot

3

at least a room for the set up, with lot of stringent

Recorder with Patient Data Management Software, Micropipettes of infrastructure is required to run a room lab
.4 Cuvette Boxes, Tip Box. It has a proper place for each and

every component of Lab
4

Customer will have 1 service provider

Different vendors are involved

5

Low voltage Consumption

High voltage required (400watt-5000watt)

4 hour power back up via battery packs and Solar Panel which

No Back up

6

can also be extended

7

High investment on space and power

The whole lab can operate using a solar panel/battery for 24hrs
with v. low cost

8

Temperature should not be maintained (no warm up and

Stringent conditions needed to maintain temperature and humidity

cooling time for operations), independent of humidity Lab

for usage, there is warm up and cooling time

designed from 0 deg to 50 deg C
9

LED technology is used which prevents break downs

Lamps are used (Halogen) which is prone to frequent breakdowns

10

Maintenance free

Maintenance free

11

Running Cost is low because of following factors

Running cost is high

1) Blood collection cost (no vials, transportation of sample, anti coagulants, EDTA vials not required)
2) Power Consumption is less

Semi Automatic Analyzer
Power Supply

Consumables &
Reagents Specific

+-220v AC
Yes - Closed system

Accurate All

Accukine - Upgraded Version

12v DC

12 vDC

No - Open System

No - Open System

Yes Pass 2ft drop test

Yes Pass 2ft drop test

Portability & Rugged Ability

No

Sample Required

1.0ml

Light Source

Lamps

LED that prevents frequent breakdowns
frequent breakdowns

UV & Visible light

filters

Virtual filters

0.5ml

0.5ml

LED that prevents frequent breakdowns
UV & Visible light

Virtual filters

Flow Cell

Sucking mechanism

Sucking mechanism required which
reduces complexity and delicacy in sample
reading and sample analysis,

No pump system required which reduces
complexity and delicacy in sample reading
sample analysis,

Method

End point. Kinetic method

End point, Creatinine only with Kinetic method

End point, Kinetic method, Fixed point

Reading Time

5 sec

Test performed

Haematology and electrolytes can't be
performed

Temp. Required

It should be maintained

Maintenance

Highly sensitive

Climate & humidity independent No. needs stringent laboratory controlled
conditions
User friendly

User friendly

2 sec

36 tests : 31 biochemistry with electrolytes &
5 haematology parameters

37 tests 32 biochemistry with electrolytes
& 5 haematology parameters

Not required

Not required

Rugged/Maintenance free

Rugged/Maintenance free

Yes, stable in all environment

Yes, stable in all environment

User friendly

Weight

Weight

600 Gm.

Warm up time & Cooling Time

3 -5 minutes

Not required

Modes operation

Tough

Economical

High cost

Accuracy/Li near

linear

Life

2 sec

Easy
1/3 of an analyzer(Highly economical)

Highly linear
5 times more than an analyzer

Yes

600 Gm.
Not required
Easy

1/3 of an analyzed Highly economical)____
Highly linear

5 times more than an analyzer______

Position: 73 (42 views)